Pepper-computer Modular Computers RS485 Bedienungsanleitung Seite 173

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 320
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 172
SMART I/O Users Manual
©1996 PEP Modular Computers GmbHMarch 12, 1996 Page 5 - 17
5
Chapter 5 Analog Modules
5.1.8.2 SMDAD1Init
Syntax
error_code SMDAD1Init(u_int8 PortNr);
Description
This function initializes the resources needed to use the SM-DAD1 on port
PortNr, including:
- testing of the SM-Module ID;
- reading the factory-set conversion table held in the EEPROM;
- setting the ADC to bipolar mode and the DAC to unipolar mode;
- fetching the resources.
Input
u_int8 PortNr
SM-Port number to initialize
(from 0 to 10)
Output
error_code SUCCESS or
E_BMODE if wrong or no module
E_MEMFUL if no memory resources available
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
Example
RetVal = SMDAD1Init(0);
Note
If the same SM-DAD1 Module is to be accessed from different tasks, the
user must make sure that the actual output status is ensured by using for
example, semaphores within OS-9.